Fire Pumps CHAPTER 4 - NFPA
[NFPA 20-10: 4.2.3] Each pump, driver, controlling equipment, power supply and arrangement, and liquid supply shall be approved by the authority having jurisdiction for the specific field conditions encountered. [NFPA 20-10: 4.2.4] ... View Full Source

Fire pump - Wikipedia
The main code that governs fire pump installations in North America is the National Fire Protection Association's NFPA 20 Standard for the causing the fire pump to start. The jockey pump is essentially a and to provide 10psi more pressure than the main fire pump (As per Code IS ... Read Article

VERTICAL TURBINE FIRE PUMPS - GeoSystems USA
VERTICAL TURBINE FIRE PUMPS Advantages of Armstrong Vertical Turbine Fire Pumps all fitted to engine, per NFPA 20, by the pump manufacturer. JOCKEY PUMP The jockey pump shall be model _____ for a ... Document Viewer

Jockey Pump Selection As Per Nfpa Pictures

Fire Pump Layout And Sizing - ABSpk
Buildings per NFPA 13 . Pump Houses 34 . Pump Houses •Setting Jockey & Main Fire Pump Start Pressures •Anywhere from 5 psi to 10 psi over main fire Fire Pump Sizing •Size selection normally varies from 90% to 140% pump capacity ... Fetch Here

Compact Fire Pump Systems - PICSA
N Aurora jockey pump n Pressure sensing lines complete per NFPA 20 n Listed OS & Y gate & butterfly valves Refer to selection tables in section 911 for selection of pump sizes and motor horsepower for specific applications. 5. ... Visit Document

Jockey Pump Selection As Per Nfpa Photos

SECTION 5.21.30 - FIRE PUMPS DESIGN AND CONSTRUCTION STANDARD
250 gpm of the rated flow of the fire pump per NFPA 20. The jockey pump shall be installed in accordance with NFPA 20. All jockey pump valves to be located as required per NFPA 20. FIRE PUMPS DESIGN AND CONSTRUCTION STANDARD ... Get Doc

® DATE: AUGUST 1993 APPLICATION DATA - FIRE PUMP
FIRE PUMP AND JOCKEY PUMP SELECTION PROCEDURE STEP 1 Determine who is going to insure the property to be protected. There are four possibilities in North America a) US Stock Companies will require a “UL” label on the Fire Pump equipment which is to be built as per NFPA 20 ... Access Doc

Diesel Engines For NFPA-20 Fire Protection Applications
NFPA-20 Fire Protection Applications www.clarkefire.com. NFPA 20 –Engine Type •Diesel Engines for fire pump drive shall be of the compression ignition type. •There shall be one fuel tank per engine. ... View Doc

4857341 PJPC Jockey Pump Controller - Peerlessxnet.com
Four anchors with bolts and washers, per enclosure. Each controller has a HAND-OFF-AUTO selector switch mounted on the right-hand side for selection of Manual or Automatic operation. PJPC Instructions Jockey Pump Controllers NFPA 20 ... View This Document

Images of Jockey Pump Selection As Per Nfpa

The Jockey Pump, An Important Part Of A Fire Pump System.
Several hundred pounds per square inch. NFPA-20 Standard is the lowly Jockey Pump. First, I believe we must understand what the term Jockey Pump selection of a pump and the proper setup of the system after installation is . 5 complete. ... View This Document

FORM FOR INSPECTION, TESTING AND MAINTENANCE OF FIRE PUMPS DIESEL
FORM FOR INSPECTION, TESTING AND MAINTENANCE OF FIRE PUMPS DIESEL Information on this form covers the minimum requirements of NFPA 25-1998 for centrifugal fire pumps. T. Jockey Pump: ... Access Doc

Aurora Fire Protection Fluid Handling Solutions: Fire Pumps ...
• Aurora Jockey Pump • UL Listed Jockey Pump Controller • Pressure Sensing Lines Complete • Suction and Discharge Piping per NFPA 20 • Removable Lifting Lugs 913 Series Fire Pump Vertical Turbine Aurora Fire Protection Fluid Handling Solutions: Fire Pumps, Systems & Houses Subject: ... Access This Document

AQUA FIRE PUMPS - Isssystems.com
AQUA FIRE PUMPS FLOW HEAD PUMP MAX ELECTRIC MOTOR (HP) DIESEL ENGINE (HP) PSI (METER) MODEL BHP RPM NFPA NFPA FIRE PUMP SELECTION CHART. AQUA FIRE PUMPS NOTES: - Two models are shown must be de-rated as per NFPA standards. PERFORMANCE CURVES ... Get Document

Jockey Pump Selection As Per Nfpa Pictures

SECTION 5.21.30 - FIRE PUMP/JOCKEY PUMP DESIGN AND ...
SECTION 5.21.30 - FIRE PUMP/JOCKEY PUMP DESIGN AND CONSTRUCTION STANDARD C. Fire pump assemblies shall include a separate and dedicated jockey pump, apart from gpm of the rated flow of the fire pump per NFPA 20. ... Fetch Doc

Glossary Of Firefighting Equipment - Wikipedia
Meeting National Fire Protection Association (NFPA) Standard 1901, Motor Fire Apparatus, (44 mm) hose that carries 175 gallons per minute. Jockey pump A small pump connected to a fire sprinkler system. K ... Read Article

Instructions For Cutler-Hammer Jockey Pump Controllers
Instructions for Cutler-Hammer Jockey Pump Controllers IM05805004K. IM05805004K OVERLOAD RELAY SELECTION CHART.. 6 Page i. IM05805004K connection should be installed as per NFPA, pamphlet No. 20. NOTE: ... Document Viewer

21 30 00 Fire Protection Pumps (012914) - University Of Houston
Fire Protection Pumps 21 30 00 – 1 Fire and jockey pump cut sheets with all pump capacities, UL/FM approval, pump Provide pump accessories per NFPA 20, including, but not limited to: a. 1/2" automatic air release. ... Retrieve Doc

AURORA COMPLETE PUMP SOLUTIONS
Programs save valuable time in the selection and evaluation of pumps and systems. • Aurora Jockey Pump • Pressure Sensing Lines Complete per NfPA 20 ... Doc Retrieval

PATTERSON PUMP COMPANY
Four anchors with bolts and washers, per enclosure. selection of Manual or Automatic operation. When placed in HAND, Fire Pump Controllers & Jockey Pump Controllers NFPA 20 7-5.2.1 Water Pressure Control ... Access This Document

No comments: